Level Measurement
LIQUIDS
PRO
Radar sensor
VEGAPULS 6X
![]()
Measuring range - Distance
120 m
Process temperature
-196 ... 450 °C
All-round radar measuring device - VEGAPULS 6X combines the best of the previous VEGAPULS 60 series.
VEGAPULS can be used in almost all industrial areas and applications.
BASIC
Radar sensor
VEGAPULS C 11
With fixed cable connection Protection IP66/IP68, Type 6P
Measuring range - Distance
8 m
Process temperature
-40 ... 60 °C
For simple measuring tasks, IP66/IP68, Type 6P
Axial cable outlet, 4 ... 20 mA output, measuring range up to 8 m, accuracy ±5 mm, PVC cable with 10 m length
BASIC
Radar sensor
VEGAPULS 11
Measuring range - Distance
8 m
Process temperature
-40 ... 60 °C
For simple measuring tasks, plastic housing IP66/IP67, Type 4X
4 ... 20 mA output, measuring range up to 8 m, accuracy ±5 mm
PRO
TDR sensor
VEGAFLEX 81
Measuring range - Distance
75 m
Process temperature
-60 ... 200 °C
Universal TDR sensor for liquids of all kinds
Cable, rod or coaxial sensor. Even in applications with steam, buildup, foam or condensation, the sensor delivers precise and reliable readings – also in standpipes or bypass pipes.
PRO
Radiation-based sensor
FIBERTRAC 31
Measuring range - Distance
7 m
Accuracy
± 0.5 %
Flexible detector
The flexible detector is used on round vessels and vessels with conical outlet and is suitable for measurement of liquids, solids, slurries and suspensions. Due to its thin, flexible scintillator cross-section, FIBERTRAC 31 can be easily adapted to round vessels.
BASIC
Pressure sensor with switching function
VEGABAR 28
Measuring range - Pressure
-100 ... 6000 kPa
Process temperature
-40 ... 130 °C
With ceramic measuring cell
From thread ½", hygienic connections, universal connection G1" for hygiene adapter, 4 ... 20 mA, three-wire: PNP/NPN, 4 ... 20 mA, IO-Link, Ex and hygiene approval, coloured 360° status display
BASIC
Pressure sensor with switching function
VEGABAR 29
Measuring range - Pressure
-100 ... 100000 kPa
Process temperature
-40 ... 130 °C
With metallic measuring cell
From thread ½", hygienic connections, universal connection G1" for hygiene adapter, 4 ... 20 mA, three-wire: PNP/NPN, 4 ... 20 mA, IO-Link, Ex and hygiene approval, coloured 360° status display
BASIC
Pressure sensor with switching function
VEGABAR 38
Measuring range - Pressure
-100 ... 6000 kPa
Process temperature
-40 ... 130 °C
With ceramic measuring cell
From thread ½", hygienic connections, universal connection G1" for hygiene adapter, 4 ... 20 mA, three-wire: PNP/NPN, 4 ... 20 mA, IO-Link, Ex and hygiene approval, coloured 360° status display, on-site display and 3-button operation
BASIC
Pressure sensor with switching function
VEGABAR 39
Measuring range - Pressure
-100 ... 100000 kPa
Process temperature
-40 ... 130 °C
With metallic measuring cell
From thread ½", hygienic connections, universal connection G1" for hygiene adapter, 4 ... 20 mA, three-wire: PNP/NPN, 4 ... 20 mA, IO-Link, Ex and hygiene approval, coloured 360° status display, on-site display and 3-button operation
PRO
Pressure transmitters
VEGABAR 82
Measuring range - Pressure
-100 ... 10000 kPa
Process temperature
-40 ... 150 °C
The all-rounder with ceramic measuring cell
Universally applicable pressure transmitter. The ceramic measuring cell is resistant to temperature shocks. Can be combined with any other sensor of VEGABAR Series 80 for electronic differential pressure measurement.
PRO
Pressure transmitters
VEGABAR 81
Measuring range - Pressure
-100 ... 100000 kPa
Process temperature
-90 ... 400 °C
With chemical seal, for high temperatures
Reliable measurement of highly corrosive and hot media. Can be combined with any other sensor of VEGABAR Series 80 for electronic differential pressure measurement.
Measuring range - Pressure
-1600 ... 1600 kPa
Process temperature
-40 ... 105 °C
With metallic measuring diaphragm
For applications with liquids in small containers under simple process conditions. Possible applications can be found in almost all industrial sectors.
BASIC
Radar sensor
VEGAPULS 21
Measuring range - Distance
15 m
Process temperature
-40 ... 80 °C
For standard measuring tasks, plastic housing IP66/IP67, Type 4X
4 ... 20 mA/HART output, measuring range up to 15 m, accuracy ±2 mm, Ex approval
BASIC
Radar sensor
VEGAPULS 31
Measuring range - Distance
15 m
Process temperature
-40 ... 80 °C
For standard measuring tasks, plastic housing IP66/IP67, type 4X, display
4 ... 20 mA/HART output, measuring range up to 15 m, accuracy ±2 mm, Ex approval, on-site display and 3-button operation
BASIC
Radar sensor
VEGAPULS C 21
With fixed cable connection Protection IP66/IP68, Type 6P
Measuring range - Distance
15 m
Process temperature
-40 ... 80 °C
For standard measuring tasks, IP66/IP68, Type 6P
Axial cable outlet, measuring range up to 15 m, accuracy ±2 mm, 4 ... 20 mA, HART, SDI-12 or Modbus output, Ex-approval
BASIC
Radar sensor
VEGAPULS C 22
Measuring range - Distance
15 m
Process temperature
-40 ... 80 °C
For standard measuring tasks, IP66/IP68, Type 6P
Lateral cable outlet, measuring range up to 15 m, accuracy ±2 mm, 4 ... 20 mA, HART, SDI-12 or Modbus output, Ex approval
BASIC
Radar sensor
VEGAPULS C 23
Measuring range - Distance
30 m
Process temperature
-40 ... 80 °C
For standard measuring tasks, IP66/IP68, Type 6P
Axial cable outlet, measuring range up to 30 m, accuracy ±2 mm, 4 ... 20 mA, HART, SDI-12 or Modbus output, Ex-approval
AIR
Radar sensor
VEGAPULS Air 23
Measuring range - Distance
3 m
Process temperature
-20 ... 60 °C
Autarkic sensor with measured value transmission by radio technology
NB-IoT/CAT-M1, LoRa, measuring range up to 3m, accuracy +/-5mm
AIR
Radar sensor
VEGAPULS Air 41
Measuring range - Distance
15 m
Process temperature
-20 ... 60 °C
Autarkic sensor with measured value transmission by radio technology
NB-IoT/CAT-M1, LoRa, measuring range up to 15m, accuracy +/-2mm
AIR
Radar sensor
VEGAPULS Air 42
Measuring range - Distance
30 m
Process temperature
-20 ... 60 °C
Autarkic sensor with measured value transmission by radio technology
NB-IoT/CAT-M1, LoRa, measuring range up to 30m, accuracy +/-2mm
PRO
TDR sensor
VEGAFLEX 83
Measuring range - Distance
32 m
Process temperature
-40 ... 150 °C
For aggressive media or extremely high hygienic requirements
PFA coated or polished sensor. Even in applications with steam, buildup, foam or condensation, the sensor delivers precise and reliable readings.
PRO
TDR sensor
VEGAFLEX 86
Measuring range - Distance
75 m
Process temperature
-196 ... 450 °C
For the most extreme process conditions
Cable, rod or coaxial sensor. Its robust, mechanical design and the second process seal, the Second Line of Defense, protect the sensor for demanding measurement tasks. Process temperature: -196 ... 450° C; process pressure: -1 … 400 bar
BASIC
Ultrasonic sensor
VEGASON S61
Measuring range - Distance
5 m
Process temperature
-40 ... 80 °C
Measures liquids up to 5 m and bulk solids up to 2 m away
Output signal 4 ... 20 mA, Ex approval and PLICSCOM optional.
PRO
Ultrasonic sensor
VEGASON 61
Fuellstandmessung Ultraschall VEGASON61
Measuring range - Distance
5 m
Process temperature
-40 ... 80 °C
Measures liquids up to 5 m and bulk solids up to 2 m away
Extensive selection of electronics, housings, approvals. Process fittings: G1½ or 1½ NPT
PRO
Ultrasonic sensor
VEGASON 62
Fuellstandmessung Ultraschall VEGASON62
Measuring range - Distance
8 m
Process temperature
-40 ... 80 °C
Measures liquids up to 8 m and bulk solids up to 3.5 m away
Extensive selection of electronics, housings, approvals. Process fittings: G2 or 2 NPT
BASIC
Ultrasonic sensor
VEGASON S62
Measuring range - Distance
8 m
Process temperature
-40 ... 80 °C
Measures liquids up to 8 m and bulk solids up to 3.5 m away
Output signal 4 ... 20 mA, Ex approval and PLICSCOM optional.
PRO
Capacitive probe
VEGACAL 62
Measuring range - Distance
6 m
Process temperature
-50 ... 200 °C
Rod probe, partly PTFE insulated
For measurement of bulk solids and non-conductive liquids such as oil. A full/empty adjustment is necessary for setup.
PRO
Capacitive probe
VEGACAL 63
Measuring range - Distance
6 m
Process temperature
-50 ... 200 °C
Rod probe, fully PE or PTFE insulated
For measurement in conductive and non-conductive liquids. A full/empty adjustment is necessary for setup.
PRO
Capacitive probe
VEGACAL 64
Measuring range - Distance
4 m
Process temperature
-50 ... 150 °C
Rod probe, fully FEP insulated
For conductive and non-conductive liquids. The rod measuring probe is fully insulated and especially suitable for viscous and adhesive products. A full/empty adjustment is necessary for setup.
PRO
Capacitive probe
VEGACAL 65
Measuring range - Distance
32 m
Process temperature
-50 ... 200 °C
Cable probe, partly PTFE insulated
For measurement of bulk solids and can also be used in non-conductive liquids such as oil. A full/empty adjustment is necessary for setup.
PRO
Capacitive probe
VEGACAL 66
Measuring range - Distance
32 m
Process temperature
-50 ... 150 °C
Cable probe, fully PTFE insulated
For use in non-abrasive liquids and bulk solids. The cable probe is fully insulated. A full/empty adjustment is necessary for setup.
PRO
Capacitive probe
VEGACAL 69
Measuring range - Distance
4 m
Process temperature
-50 ... 100 °C
Double rod probe, fully FEP insulated
For use in non-conductive vessels or corrosive liquids. The double rod probe is fully insulated and highly resistant. A full/empty adjustment is necessary for setup.
PRO
Pressure transmitters
VEGABAR 83
Measuring range - Pressure
-100 ... 100000 kPa
Process temperature
-40 ... 200 °C
With metallic measuring cell, for high pressures
For measurement of liquids and viscous products with high process pressure.
PRO
Submersible pressure transmitter
VEGAWELL 52
Measuring range - Pressure
0 ... 6000 kPa
Process temperature
-20 ... 80 °C
With ceramic measuring cell
The hydrostatic absolute pressure transmitter with ceramic measuring cell is ideal for level measurement of water/wastewater, as well as level measurement in deep wells or in tanks on ships. Maximum cable length = 1000 m.
BASIC
Submersible pressure transmitter
VEGAWELL S51
Measuring range - Pressure
0 ... 2500 kPa
Process temperature
-20 ... 60 °C
With ceramic measuring cell, standard level probe
Output signal 4 ... 20 mA, PE suspension cable, available measuring ranges: Relative pressure 0.1 / 0.2 / 0.4 / 1 / 2.5 bar, Sensor length depends on measuring range
PRO
Submersible pressure transmitter
VEGABAR 86
Measuring range - Pressure
0 ... 2500 kPa
Process temperature
-20 ... 100 °C
With ceramic measuring cell
For level measurement in wells, basins and open tanks. Maximum sensor length: Cable 250 m, tube 6 m. Can be combined with any other sensor of VEGABAR Series 80 for electronic differential pressure measurement.
PRO
Submersible pressure transmitter
VEGABAR 87
Measuring range - Pressure
0 ... 2500 kPa
Process temperature
-12 ... 100 °C
With metallic measuring cell
For level measurement of liquids and corrosive media. Maximum sensor length: Cable 250 m, tube 6 m. Can be combined with any other sensor of VEGABAR Series 80 for electronic differential pressure measurement.
PRO
Radiation-based sensor
FIBERTRAC 32
Measuring range - Distance
7 m
Accuracy
± 0.5 %
Flexible detector with higher accuracy
The flexible detector is used on round vessels and vessels with conical outlet and is suitable for measurement of liquids, solids, slurries and suspensions. Due to the larger scintillator cross-section, FIBERTRAC 32 has higher sensitivity and accuracy.
PRO
Radiation-based sensor
SOLITRAC 31
Measuring range - Distance
3 m
Accuracy
± 0.5 %
Rod detector
SOLITRAC 31 is ideal for use on cylindrical vessels, reactors, autoclaves, separators and mixing vessels. SOLITRAC offers extraordinarily high accuracy over the entire measuring range.
PRO
VEGAMAG 81
Measuring range - Distance
4 m
Process temperature
-196 ... 450 °C
Magnetic level indicator for continuous level indication without external energy