Point Level Switchs
POINT LEVEL SWITCHS
LIQUIDS
BASIC
Capacitive limit switch
VEGAPOINT 11
VEGAPOINT 11 Ultra-compact capacitive limit switch for the detection of water-based liquids
Process temperature
-20 ... 100 °C
Process pressure
-100 ... 2500 kPa
For the detection of water-based liquids
From DK > 2, from thread ½", universal connection G1" for hygiene adapter, M12, transistor output
BASIC
Capacitive limit switch
VEGAPOINT 21
Process temperature
-40 ... 115 °C
Process pressure
-100 ... 2500 kPa
For the detection of water-based liquids
From DK > 1.5, from thread ½", universal connection G1" for hygiene adapter, M12, valve plug, transistor output, IO-Link, wireless operation, Ex and hygiene approvals
PRO
Vibrating level switch
VEGASWING 61
VEGASWING 61 Vibrating level switch for liquids
Process temperature
-50 ... 250 °C
Process pressure
-100 ... 6400 kPa
For liquids (density: > 0.5 ... 2.5 g/cm³) – compact version
It detects the limit level reliably and with millimetre accuracy directly at the mounting position. Numerous process fittings, approvals as well as housing and electronics versions.
PRO
Radiation-based sensor
POINTRAC 31
Process temperature
-40 ... 60 °C
Materials, wetted parts
No wetted material
Short rod detector
The short rod detector monitors the limit level of liquids and bulk solids without contact. The sensor is used on vessels of any geometry and on pipelines.
PRO
Capacitive probe
VEGACAP 64
Process temperature
-50 ... 200 °C
Process pressure
-100 ... 6400 kPa
Rod probe, fully PTFE insulated
For adhesive liquids and light, non-abrasive bulk solids, Sensor length up to 4 m
BASIC
Compact front-flush point level switch
VEGAPOINT 24
Process temperature
-40 ... 115 °C
Process pressure
-100 ... 2500 kPa
For the detection of sticky and adhesive media
From DK > 1.5, from thread ½", universal adapter G1* for hygiene adapter M12, valve plug, transistor output, IO-Link, wireless operation, Ex and hygiene approvals
BASIC
Capacitive limit switch
VEGAPOINT 23
Process temperature
-40 ... 115 °C
Process pressure
-100 ... 2500 kPa
For the detection of water-based liquids
From DK > 1.5, from thread ½", universal connection G1" for hygiene adapter, M12, valve plug, transistor output, IO-Link, wireless operation, Ex and hygiene approvals, tube version, up to 1 m
BASIC
Vibrating level switch
VEGASWING 51
Grenzstand VEGASWING51 Gewinde
Process temperature
-40 ... 150 °C
Process pressure
-100 ... 6400 kPa
For liquids (density: > 0.5 ... 2.5 g/cm³)
It detects the limit level reliably and with millimetre accuracy directly at the mounting position. Small level switch version with stainless steel housing
PRO
Vibrating level switch
VEGASWING 63
Process temperature
-50 ... 250 °C
Process pressure
-100 ... 6400 kPa
For liquids (density: > 0.5 ... 2.5 g/cm³) – with tube extension
The position of the switching point can be up to 6 m away from the installation site. Numerous process fittings, approvals as well as housing and electronics versions.
PRO
Vibrating level switch
VEGASWING 66
VEGASWING 66 Vibrationsgrenzschalter für Flüssigkeiten bei extremen Prozesstemperaturen und -drücken
Process temperature
-196 ... 450 °C
Process pressure
-100 ... 16000 kPa
For liquids (density: > 0.42 ... 2.5 g/cm³) – high temperature version
Configurable both as compact version and version with tube extension up to 3 m. Numerous process fittings, approvals as well as housing and electronics versions.
PRO
Capacitive probe
VEGACAP 62
Process temperature
-50 ... 200 °C
Process pressure
-100 ... 6400 kPa
Rod probe, partly PTFE insulated
For liquids and bulk solids, Sensor length up to 6 m
PRO
Capacitive probe
VEGACAP 63
Process temperature
-50 ... 200 °C
Process pressure
-100 ... 6400 kPa
Rod probe, fully PE or PTFE insulated
For liquids and bulk solids, non-abrasive, Sensor length up to 6 m
PRO
Capacitive probe
VEGACAP 65
Process temperature
-50 ... 200 °C
Process pressure
-100 ... 6400 kPa
Cable probe, partly PTFE insulated
For liquids and bulk solids, Sensor length up to 32 m
PRO
Capacitive probe
VEGACAP 66
Process temperature
-50 ... 150 °C
Process pressure
-100 ... 4000 kPa
Cable probe, fully PTFE insulated
For non-abrasive liquids and bulk solids, Sensor length up to 32 m
PRO
Capacitive probe
VEGACAP 69
Process temperature
-50 ... 100 °C
Process pressure
-100 ... 200 kPa
Double rod probe, fully FEP insulated
For liquids, also in non-conductive containers, Sensor length up to 4 m
BASIC
Capacitive probe
VEGACAP 27
Kapazitiver Grenzschalter zur Grenzstanderfassung VEGACAP27
Process temperature
-50 ... 200 °C
Process pressure
-100 ... 6300 kPa
Rod probe, fully PTFE or PFA insulated
For liquids, also in non-conductive containers, Sensor length up to 4 m
BASIC
Capacitive probe
VEGACAP 98
Abgleichfreier anhaftungsneutraler Kompaktgrenzschalter VEGACAP98
Process temperature
-40 ... 80 °C
Process pressure
100 ... 100 kPa
Rod probe, made of PP
For liquids and bulk solids, adjustment-free setup, Sensor length up to 2 m
BASIC
Conductive level switch
VEGAKON 61
KON61 Konduktiver Grenzschalter fuer Fluessigkeiten
Process temperature
-40 ... 150 °C
Process pressure
-100 ... 2500 kPa
Compact level switch with partial PTFE insulation
For front-flush installation. The instrument is ideally suited as full or empty detector in pipelines.
BASIC
Conductive level switch
VEGAKON 66
KON66 Konduktiver Mehrstabgrenzschalter fuer Fluessigkeiten
Process temperature
-40 ... 100 °C
Process pressure
-100 ... 600 kPa
Multiple rod level switch with PP insulation
With 2 to 3 rods, a corresponding number of switching points between 12 cm and 4 m can be realized.
BASIC
Conductive probe
EL 1
EL1 Konduktive PTFE teilisolierte Stabmesssonde
Process temperature
-50 ... 130 °C
Process pressure
-100 ... 6300 kPa
Rod electrode with PTFE insulation
Rod electrode with a rod up to 4 m long. Extended temperature range through PTFE insulation. A VEGATOR 130 series controller is required for operation.
BASIC
Conductive probe
EL 3
EL3 Konduktive PTFE teilisolierte Mehrstabmesssonde
Process temperature
-50 ... 130 °C
Process pressure
-100 ... 6300 kPa
Rod electrodes with PTFE insulation
With 2 to 5 rods, a corresponding number of switching points between 5 cm and 6 m can be realized. Extended temperature range through PTFE insulation. A VEGATOR 130 series controller is required for operation.
BASIC
Conductive probe
EL 4
EL4 Konduktive PP teilisolierte Mehrstabmesssonde
Process temperature
-20 ... 100 °C
Process pressure
-100 ... 600 kPa
Rod electrodes with PP insulation
With 2 to 5 rods, a corresponding number of switching points between 10 cm and 4 m can be realized. A VEGATOR 130 series controller is required for operation.
BASIC
Conductive probe
EL 6
EL6 Konduktive PP FEP teilisolierte Mehrstabmesssonde
Process temperature
-20 ... 100 °C
Process pressure
-100 ... 600 kPa
Cable electrodes with FEP insulation
With 2 to 5 cables, a corresponding number of switching points between 22 cm and 60 m can be realized. A VEGATOR 130 series controller is required for operation.
BASIC
Conductive probe
EL 8
EL8 Konduktive PE teilisolierte Stabmesssonde
Process temperature
-10 ... 60 °C
Process pressure
-100 ... 600 kPa
Rod electrodes with PE insulation
Rod electrode with a rod up to 3 m long. A VEGATOR 130 series controller is required for operation.
PRO
Microwave barrier
VEGAMIP R61
Measuring range - Distance
100 m
Process temperature
-40 ... 80 °C
Microwave receiver
The simple and robust measuring system is virtually independent of the process and the chemical and physical properties of the product. Also suitable for detection of objects, such as vehicles or ships, or detection of solid materials on conveyor belts.
PRO
Microwave barrier
VEGAMIP R62
Measuring range - Distance
100 m
Process temperature
-40 ... 80 °C
Microwave receiver, detached version
The non-contact measuring method has no direct contact with the medium and thus warranties continuous, wear and maintenance free operation. Detached version for use in poorly accessible or dangerous mounting locations.
BASIC
Vibrating level switch
VEGASWING 53
Process temperature
-40 ... 150 °C
Process pressure
-100 ... 6400 kPa
For liquids (density: > 0.5 ... 2.5 g/cm³) – with tube extension
The position of the switching point can be up to 1 m away from the installation location.